Locomotors Rehabilitation System via Gait Analysis with Load cell, Gyroscope and Accelerometer Sensor

Authors

  • Muhammad Rosli Abdullah UniKL British Malaysian Institute, Batu 8, Jln Sg. Pusu, 53100, Gombak Selangor, Malaysia.
  • Nur Ezzati Shaiful Alam UniKL British Malaysian Institute, Batu 8, Jln Sg. Pusu, 53100, Gombak Selangor, Malaysia.
  • Muhamad Khusaini Abdul Ghani Ibu Pejabat MARA, No.21, Jalan Raja Laut, 50609, Kuala Lumpur, Malaysia.
  • M. Mahadi Abdul Jamil Universiti Tun Hussien Onn Malaysia, 86400 Parit Raja, Batu Pahat, Johor, Malaysia
  • Safyzan Salim Universiti Tun Hussien Onn Malaysia, 86400 Parit Raja, Batu Pahat, Johor, Malaysia

Keywords:

Gait analysis, Locomotors Rehabilitation System, Embedded System, Load cell, Accelerometer, Gyroscope

Abstract

Locomotors Rehabilitation System (LRS) has a potential used with the advancement in electronic and computer. It requires sensors for a locomotion measurement and units to communicate between patients and the doctors. These promote a flexible and economical solution to a Gait analysis by develops units to differentiate the abnormal and normal patient different walking pattern. The LRS consist of a PIC microcontroller, RF transceiver, analogue multiplexer plus sensors for the compressive force, acceleration and angular velocity measurement. Later, these measurements are sent to the computer for further human locomotion analysis. The data transmission is optimized up to 250 meters line of sight with ±3 g acceleration, tilt angle at ± 0.1 ° and ≤ 150 Kg bodyweight measurement. The LRS is expected to offer more information than the Gait analysis and also the ability to improve the clinical and rehabilitation applications.

Downloads

Download data is not yet available.

Author Biographies

  • Muhammad Rosli Abdullah, UniKL British Malaysian Institute, Batu 8, Jln Sg. Pusu, 53100, Gombak Selangor, Malaysia.
    Department of Medical Electronics
  • Nur Ezzati Shaiful Alam, UniKL British Malaysian Institute, Batu 8, Jln Sg. Pusu, 53100, Gombak Selangor, Malaysia.
    Department of Medical Electronics
  • Muhamad Khusaini Abdul Ghani, Ibu Pejabat MARA, No.21, Jalan Raja Laut, 50609, Kuala Lumpur, Malaysia.

    Unit Perhubungan Dan Antarabangsa,
    Bahagian Kemahiran Teknikal,

  • M. Mahadi Abdul Jamil, Universiti Tun Hussien Onn Malaysia, 86400 Parit Raja, Batu Pahat, Johor, Malaysia

    Department of Electronic Engineering
    Modeling and Simulation Research Laboratory,

  • Safyzan Salim, Universiti Tun Hussien Onn Malaysia, 86400 Parit Raja, Batu Pahat, Johor, Malaysia
    Department of Electronic Engineering
    Modeling and Simulation Research Laboratory,

Downloads

Published

09-10-2015

Issue

Section

Issue on Electrical and Electronic Engineering

How to Cite

Abdullah, M. R., Shaiful Alam, N. E., Abdul Ghani, M. K., Abdul Jamil, M. M., & Salim, S. (2015). Locomotors Rehabilitation System via Gait Analysis with Load cell, Gyroscope and Accelerometer Sensor. International Journal of Integrated Engineering, 7(3). https://penerbit.uthm.edu.my/ojs/index.php/ijie/article/view/1227

Most read articles by the same author(s)