Metallic Cylinder Reflected Power Measurement For 93.1GHz Frequency Modulated Continuous Wave Radar Calibration

Authors

  • P. N. Ja’afar Universiti Teknologi Malaysia, Johor Bahru, 81310 Johor, MALAYSIA
  • S. M. Idrus Universiti Teknologi Malaysia, Johor Bahru, 81310 Johor, MALAYSIA
  • S. Ambran Universiti Teknologi Malaysia, Johor Bahru, 81310 Johor, MALAYSIA
  • N. A. Yusri Universiti Teknologi Malaysia, Johor Bahru, 81310 Johor, MALAYSIA
  • N. Mohamed Universiti Teknologi Malaysia, Johor Bahru, 81310 Johor, MALAYSIA
  • A. Hamzah Universiti Teknologi Malaysia, Johor Bahru, 81310 Johor, MALAYSIA
  • N. Shibagaki Hitachi Kokusai Electric Inc., Tokyo 187-8511, Japan
  • K. Kashima Hitachi Kokusai Electric Inc., Tokyo 187-8511, Japan
  • T. Hayashi Link Laboratory Inc., Tokyo 185-0014, Japan

Keywords:

FMCW radar, foreign object debris, radar cross section, calibration, millimeter-wave, runway airport

Abstract

A metallic cylinder is one of the best materials and shapes to calibrate a radar system performance. The measurement of a 4cm diameter and 3cm-height metallic cylinder as a target has been presented for the analysis at the millimeter-wave (mm-wave) spectrum. This experiment was conducted in a real airport environment at Kuala Lumpur International Airport considering clear sky conditions. The measurement was carried out at 93.1 GHz which uses Frequency Modulated Continuous Wave (FMCW) radar to consistently detect the target. The radar cross-section (RCS) of the metallic cylinder is measured with respect to the angle of runway pavement. It is found that the measurements exhibited smaller RCS value with an average of –43.47 dBsm at a longer range compared to –30.16 dBsm at a shorter range with a total change of 13.31 dBsm. The reflectivity characteristics of the radar target, theoretical measurement of the metallic cylinder, its incident angle from the radar target, and measurement evaluation are presented in this paper.

Downloads

Download data is not yet available.

Downloads

Published

15-08-2023

Issue

Section

Special Issue 2023: MJWRT2022

How to Cite

Ja’afar, P. N. ., Idrus, S. M., Ambran, S., Yusri, N. A. ., Mohamed, N. ., Hamzah, A. ., Shibagaki, N., Kashima, K. ., & Hayashi, T. . (2023). Metallic Cylinder Reflected Power Measurement For 93.1GHz Frequency Modulated Continuous Wave Radar Calibration. International Journal of Integrated Engineering, 15(3), 187-192. https://penerbit.uthm.edu.my/ojs/index.php/ijie/article/view/12889

Most read articles by the same author(s)