Comprehensive Energy Performance Assessment of a Lecturer Building in a Malaysian Public University

Authors

  • Norfakhira Mohd Nor Faculty of Mechanical & Manufacturing Engineering, Universiti Tun Hussein Onn Malaysia, 86400 Parit Raja, Batu Pahat, Johor, MALAYSIA
  • Mohd Azahari Razali Faculty of Mechanical & Manufacturing Engineering, Universiti Tun Hussein Onn Malaysia, 86400 Parit Raja, Batu Pahat, Johor, MALAYSIA
  • Nur Syafiqah Adha Narrudin Faculty of Mechanical & Manufacturing Engineering, Universiti Tun Hussein Onn Malaysia, 86400 Parit Raja, Batu Pahat, Johor, MALAYSIA
  • Nur Adlin Abu Bakar Department of Science of Technology Innovation, Nagoaka University of Technology, Nagoaka, Niigata, JAPAN
  • Siti Birkha Mohd Ali Department of Engineering, Faculty of Engineering and Life Sciences, Universiti Selangor, Malaysia
  • Nur Erma Nardiah Nazami Sanaiden Group Berhad, Level 8, Uptown 1, No. 1 Jalan SS21/58, Damansara Utama, 47400 Petaling Jaya, Selangor, MALAYSIA
  • Masataro Suzuki Department of System Safety Engineering, Institute of GIGAKU, Nagaoka University of Technology, Nagoaka, Niigata, JAPAN

Keywords:

Energy performance, energy audit, air-conditioning load, load apportioning, MS1525 compliance

Abstract

The increasing energy consumption of public university buildings in Malaysia has raised concern, particularly regarding the energy performance of lecturer rooms which is a topic often overlooked in broader campus-level studies. This research addresses that gap by analysing the energy usage patterns of the C16 lecturer building at Universiti Tun Hussein Onn Malaysia (UTHM). Previous studies have lacked continuous monitoring and system-level differentiation, limiting insights into specific energy demands. In contrast, this study uses detailed energy audits, data logging, and visual inspections to assess lighting and air-conditioning performance based on Malaysian Standard MS1525. Findings reveal that air-conditioning dominates energy use, accounting for 94% of total consumption, while lighting contributes only 6%. Usage patterns align with occupancy and time of day, and several areas exhibit deviations from recommended lighting and HVAC conditions. These results highlight key opportunities for energy conservation measures such as HVAC system optimization, lighting controls, and improved insulation. The study provides practical guidance for improving energy efficiency in academic buildings and underscores the importance of room-level profiling in tropical climates. 

Downloads

Download data is not yet available.

Author Biographies

  • Norfakhira Mohd Nor, Faculty of Mechanical & Manufacturing Engineering, Universiti Tun Hussein Onn Malaysia, 86400 Parit Raja, Batu Pahat, Johor, MALAYSIA

    Faculty of Mechanical & Manufacturing Engineering, Universiti Tun Hussein Onn Malaysia, 86400 Parit Raja, Batu Pahat, Johor, MALAYSIA

  • Mohd Azahari Razali, Faculty of Mechanical & Manufacturing Engineering, Universiti Tun Hussein Onn Malaysia, 86400 Parit Raja, Batu Pahat, Johor, MALAYSIA

    Faculty of Mechanical & Manufacturing Engineering, Universiti Tun Hussein Onn Malaysia, 86400 Parit Raja, Batu Pahat, Johor, MALAYSIA

  • Nur Syafiqah Adha Narrudin, Faculty of Mechanical & Manufacturing Engineering, Universiti Tun Hussein Onn Malaysia, 86400 Parit Raja, Batu Pahat, Johor, MALAYSIA

    Faculty of Mechanical & Manufacturing Engineering, Universiti Tun Hussein Onn Malaysia, 86400 Parit Raja, Batu Pahat, Johor, MALAYSIA

  • Nur Adlin Abu Bakar, Department of Science of Technology Innovation, Nagoaka University of Technology, Nagoaka, Niigata, JAPAN

    Department of Science of Technology Innovation, Nagoaka University of Technology, Nagoaka, Niigata, JAPAN

  • Siti Birkha Mohd Ali, Department of Engineering, Faculty of Engineering and Life Sciences, Universiti Selangor, Malaysia

    Department of Engineering, Faculty of Engineering and Life Sciences, Universiti Selangor, Malaysia

  • Nur Erma Nardiah Nazami, Sanaiden Group Berhad, Level 8, Uptown 1, No. 1 Jalan SS21/58, Damansara Utama, 47400 Petaling Jaya, Selangor, MALAYSIA

    Sanaiden Group Berhad, Level 8, Uptown 1, No. 1 Jalan SS21/58, Damansara Utama, 47400 Petaling Jaya, Selangor, MALAYSIA

  • Masataro Suzuki, Department of System Safety Engineering, Institute of GIGAKU, Nagaoka University of Technology, Nagoaka, Niigata, JAPAN

    Department of System Safety Engineering, Institute of GIGAKU, Nagaoka University of Technology, Nagoaka, Niigata, JAPAN

Downloads

Published

28-04-2026

How to Cite

Norfakhira Mohd Nor, Razali, M. A., Nur Syafiqah Adha Narrudin, Nur Adlin Abu Bakar, Siti Birkha Mohd Ali, Nur Erma Nardiah Nazami, & Masataro Suzuki. (2026). Comprehensive Energy Performance Assessment of a Lecturer Building in a Malaysian Public University. International Journal of Integrated Engineering, 18(2), 42-55. https://penerbit.uthm.edu.my/ojs/index.php/ijie/article/view/23162